Use challenge samples that represent the decision boundary
Inspection should be tested with known acceptable and unacceptable conditions, including realistic variation near the agreed limit. Artificial samples may be useful for setup but should not replace production-intent challenge samples where the defect depends on material, print, product or pack geometry.